Summary for Test 2019-12-04-2-2
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 214329 DEA: 120S2404 EFIS: 1220000002 |
---|---|
DIST-CO-RTE-PM | 12-ORA-91,90-6.42/6.5, 6.42 |
Award Date | 07/23/2019 |
Closeout Date | Not set |
Work Description | repair a damage steel girder by heat straightening as a result of a high load vehicle hit |
Location Description | Westbound Route 91 at La Palma Avenue Bridge Structure at PM 6.42 |
QA Service Level | 1 (Verified on 08/15/2019) |
Sample Information
Sample Taken Date | 12/04/2019 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/09/2019 |
Sample type | Quality Assurance | A brief description of the sample | 3/4"-10 x 4-3/4" A325 |
The quantity of what the sample constitutes | 64 | From where was the sample collected | Other |
First name of sampler or witnessed by | Kenneth | Last name of sampler or witnessed by | Varela |
Title of sampler | Associate Steel Inspector | Telephone number of sampler | (562) 440-7716 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Nucor Fastener Division | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L08-067-19 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 373512AR |
---|---|---|---|
Heat Number(s) | NF15204190 | Nut Mfg. Lot Number(s) | 425734B |
Washer Mfg. Lot Number(s) | 317650 | Bolt Specification | ASTM A325 |
Bolt Length(s) | 4-3/4" | Nut Specification | ASTM A563 Gr. DH |
Washer Specification | ASTM 436 | Finish | HDG |
Diameter/Size | 3/4"-10 | Bolt Mfg. Lot Number | 373512A |
Rocap Test Requirement(s) | Yes | Lubricant Requirements(s) | Yes |
Test Details
DIME Sample ID: 2019-12-04-2
DIME Test ID: 2019-12-04-2-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2019-12-11
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 12/10/2019
UTM: 450kip
Temperature: 72 f
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1A | 425734B | 50949 | Nut Proof Load | spaine |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.