Summary for Test 2019-11-15-18-6
Test performed: CTM 204-June 2010Project Information
Project Identifiers | DEA: No Project |
---|---|
DIST-CO-RTE-PM | --- |
Award Date | Not set |
Closeout Date | 11/01/2022 |
Work Description | Special project identifier for material not associated with a project |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 11/15/2019 | Sample Unique Key | 18 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/15/2019 |
Sample type | Verification | A brief description of the sample | Virgin 1/2-inch Type A Aggregate |
The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Source |
First name of sampler or witnessed by | Adam | Last name of sampler or witnessed by | Zeither |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Vulcan Pleasanton | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA or name of Pit) | 91-01-0010::CALMAT/PLEASANTON |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | Hot Drop |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 1/2 inch |
The concrete mix design number | Unknown | Lot number | Unknown |
Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2019-11-15-18
DIME Test ID: 2019-11-15-18-6
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)
Test Release Date: 2019-11-17
Test Results
The test method used?: Plastic Index
Input Type: Calculated
Tester's full name: Clinton Edmiston
Date of test: 11/15/2019
Liquid Limit (LL): 0 %
Plastic Limit (PL): 0 %
Plastic Index(PI): NP
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/17/2019 ✔