Summary for Test 2014-08-19-8-3
Test performed: CTM 229-June 2011Project Information
Project Identifiers | Project ID: 7613 DEA: 071218W4 EFIS: 0700021119 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-29.4/31.6 |
Award Date | 11/29/2012 |
Closeout Date | 07/31/2023 |
Work Description | REALIGN ROUTE 5 AND RAILROAD TRACKS AND RECONFIGURE ON- AND OFF-RAMPS. |
Location Description | LOS ANGELES COUNTY IN BURBANK FROM WEST MAGNOLIA BOULEVARD OVERCROSSING TO 0.3 MILE NORTH OF BUENA VISTA STREET/WINONA AVENUE UNDERCROSSING |
QA Service Level | 1 (Verified on 10/08/2012) |
Sample Information
Sample Taken Date | 08/19/2014 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/19/2014 |
Sample type | Department Acceptance | A brief description of the sample | Class 3 Aggregate Base |
The quantity of what the sample constitutes | 1 Bucket | From where was the sample collected | Source |
First name of sampler or witnessed by | Dan | Last name of sampler or witnessed by | Chapman |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | 4235B | Linked DIME Sample ID | 0 |
The fabricator/manufacturer/facility name | Unknown | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Unknown |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | 210 Fwy crushing site west of Latunga Canyon |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | |
The concrete mix design number | Lot number | Not set | |
Sublot number | Not set | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2014-08-19-8
DIME Test ID: 2014-08-19-8-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 229-June 2011: Method of Test for Durability Index
Test Release Date: 2015-02-20
Test Results
What test(s) are being run?: Coarse durability and fine durability
Input Type: Calculated
Tester's full name: Martin Ruiz
Date of test: 08/22/2014
Coarse durability index: 75
Fine durability index: 48
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/20/2015 ✔