Summary for Test 2014-08-19-8-3

Test performed: CTM 229-June 2011

Project Information

Project IdentifiersProject ID: 7613
DEA: 071218W4
EFIS: 0700021119
DIST-CO-RTE-PM07-LA-5-29.4/31.6
Award Date11/29/2012
Closeout Date07/31/2023
Work DescriptionREALIGN ROUTE 5 AND RAILROAD TRACKS AND RECONFIGURE ON- AND OFF-RAMPS.
Location DescriptionLOS ANGELES COUNTY IN BURBANK FROM WEST MAGNOLIA BOULEVARD OVERCROSSING TO 0.3 MILE NORTH OF BUENA VISTA STREET/WINONA AVENUE UNDERCROSSING
QA Service Level1 (Verified on 10/08/2012)

Sample Information

Sample Taken Date08/19/2014 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/19/2014
Sample typeDepartment Acceptance A brief description of the sampleClass 3 Aggregate Base
The quantity of what the sample constitutes1 Bucket From where was the sample collectedSource
First name of sampler or witnessed byDan Last name of sampler or witnessed byChapman
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identification4235B Linked DIME Sample ID0
The fabricator/manufacturer/facility nameUnknown Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Unknown
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collected210 Fwy crushing site west of Latunga Canyon
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size
The concrete mix design number Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2014-08-19-8
DIME Test ID: 2014-08-19-8-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 229-June 2011: Method of Test for Durability Index
Test Release Date: 2015-02-20

Test Results


What test(s) are being run?: Coarse durability and fine durability
Input Type: Calculated
Tester's full name: Martin Ruiz
Date of test: 08/22/2014
Coarse durability index: 75
Fine durability index: 48
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/20/2015