Summary for Test 2019-09-24-3-2

Test performed: ASTM F606-14a

Project Information

Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Award DateNot set
Closeout Date11/01/2022
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date09/24/2019 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing09/26/2019
Sample typeQuality Assurance A brief description of the sample1"-8 ASTM A563-DH Galvanized Heavy Hex Nut
The quantity of what the sample constitutes7 of 24,300 From where was the sample collectedDistributor
First name of sampler or witnessed byBrian Last name of sampler or witnessed byMurray
Title of samplerQA Inspector Telephone number of sampler213 435 4055
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameUnytite Inc Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL140-003-19 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)n/a
Heat Number(s)190424 Nut Mfg. Lot Number(s)3109-S-190424
Washer Mfg. Lot Number(s)n/a Bolt Specificationn/a
Bolt Length(s) Nut SpecificationASTM A563-DH
Washer Specificationn/a Finish
Diameter/Size1" Bolt Mfg. Lot Number
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2019-09-24-3
DIME Test ID: 2019-09-24-3-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2019-10-15

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 10/10/2019
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11B31019-S-19042492083Nut Proof Loadspaine

General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 10/15/2019