Summary for Test 2019-08-16-14-4
Test performed: AASHTO T283-14Project Information
Project Identifiers | DEA: No Project |
---|---|
DIST-CO-RTE-PM | --- |
Award Date | Not set |
Closeout Date | 11/01/2022 |
Work Description | Special project identifier for material not associated with a project |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 08/16/2019 | Sample Unique Key | 14 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/23/2019 |
Sample type | Verification | A brief description of the sample | Aggregate, Loose Mix, Asphalt, LAS, RAP |
The quantity of what the sample constitutes | One JMF Verification | From where was the sample collected | Source |
First name of sampler or witnessed by | Tom | Last name of sampler or witnessed by | Cromwell |
Title of sampler | MNS Consultant | Telephone number of sampler | |
Laboratory sample identification | 19-J-045 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Papich Paso Robles | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | Unknown |
Sublot number | Unknown | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2019-08-16-14
DIME Test ID: 2019-08-16-14-4
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Test Release Date: 2019-09-26
Test Results
Input Type: Calculated
Tester's full name: G3
Date of test: 08/23/2019
Specimen Treatment: Treated
Average Dry Tensile Strength: 241 psi
Average Wet Tensile Strength: 198 psi
Tensile Strength Ratio: 82
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/26/2019 ✔