Summary for Test 2019-02-18-21-8
Test performed: CTM 204-June 2010Project Information
| Project Identifiers | DEA: No Project |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | 11/01/2022 |
| Work Description | Special project identifier for material not associated with a project |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 02/18/2019 | Sample Unique Key | 21 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 02/18/2019 | Sample type | Preliminary |
| A brief description of the sample | JMF 1/2 Cold feed | The quantity of what the sample constitutes | JMF |
| From where was the sample collected | Source | First name of sampler or witnessed by | Carlos |
| Last name of sampler or witnessed by | Manzo | Title of sampler | QC Technician |
| Telephone number of sampler | Laboratory sample identification | TEM12SPLA | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | SPM-Templeton | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-10-0006::AVENAL AGGREGATES |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
| The plant number | Unknown | A detailed description of where the material sample was collected | Cold Feed |
| Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 1/2 inch |
| The concrete mix design number | Unknown | Lot number | Unknown |
| Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2019-02-18-21
DIME Test ID: 2019-02-18-21-8
Testing Lab: Sierra Pacific Materials
Test Method: CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)
Test Release Date: 2019-07-30
Test Results
The test method used?: Plastic Index
Input Type: Calculated
Tester's full name: unknown
Date of test: 02/18/2019
Liquid Limit (LL): 1 %
Plastic Limit (PL): 1 %
Plastic Index(PI): NP
General comments (publicly viewable) (Max 1000 characters): 3512 does not provide individual LL and PL results, only PI
Test was verified on 7/30/2019 ✔