Summary for Test 2019-04-01-20-1

Test performed: AASHTO T27-14

Project Information

Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Award DateNot set
Closeout Date11/01/2022
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date04/01/2019 Sample Unique Key20
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/01/2019
Sample typeQuality Control A brief description of the sampleCrusher Dust (Untreated)
The quantity of what the sample constitutesMix Design From where was the sample collectedSource
First name of sampler or witnessed byCGI Last name of sampler or witnessed byCGI
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameShaw Pit Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-25-0008::SHAW PIT
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sample19-1278.105A
The plant numberUnknown A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/4 inch
The concrete mix design number19-04-S1a Lot number0
Sublot number0 Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-04-01-20
DIME Test ID: 2019-04-01-20-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2019-05-08

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: CGI
Date of test: 04/01/2019
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 100 %
Cumulative percent passing the 3/8 in. sieve: 100 %
Cumulative percent passing the 1/4 in. sieve: 93.5 %
Cumulative percent passing the #4 sieve: 87 %
Cumulative percent passing the #8 sieve: 50 %
Cumulative percent passing the #16 sieve: 32 %
Cumulative percent passing the #30 sieve: 23 %
Cumulative percent passing the #50 sieve: 17 %
Cumulative percent passing the #100 sieve: 14 %
Cumulative percent passing the #200 sieve: 13 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/8/2019