Summary for Test 2019-04-15-1-3
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 213470 DEA: 06394604 EFIS: 0600020595 |
---|---|
DIST-CO-RTE-PM | 06-FRE-269-10.6/12.4 |
Award Date | 11/02/2018 |
Closeout Date | 10/15/2020 |
Work Description | REPLACE BRIDGES AND RECONSTRUCT ROADWAY. |
Location Description | FRESNO COUNTY NEAR HURON FROM 1.0 MILE NORTH OF PALMER AVENUE TO 0.4 MILE SOUTH OF ROUTE 198 |
QA Service Level | 1 (Verified on 09/25/2018) |
Sample Information
Sample Taken Date | 04/15/2019 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 04/17/2019 |
Sample type | Quality Assurance | A brief description of the sample | #5 Hoop 1'4" diameter |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Arthur | Last name of sampler or witnessed by | Peterson |
Title of sampler | QA Inspector | Telephone number of sampler | 707-342-8602 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | TNT Rebar | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 066919 |
Hoop Manufacturer Lot Number(s) | Lot 61 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | 5 |
Diameter of Hoop | 1'-4" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | Cascade Steel |
Welding Company | TNT Rebar | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2019-04-15-1
DIME Test ID: 2019-04-15-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2019-04-30
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 04/23/2019
UTM: 400KIP
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 3 | 61 | #5/16mm | 0.31 | 29780 | 96060 | Bar Broke | Brian |
General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 4/23/2019 ✔