Summary for Test 2019-01-16-3-4
Test performed: ASTM F606-14aProject Information
Project Identifiers | DEA: No Project |
---|---|
DIST-CO-RTE-PM | --- |
Award Date | Not set |
Closeout Date | 11/01/2022 |
Work Description | Special project identifier for material not associated with a project |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 01/16/2019 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/21/2019 |
Sample type | Quality Assurance | A brief description of the sample | F1554 Grade 105 HDG Anchor Bolts |
The quantity of what the sample constitutes | 200 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | William | Last name of sampler or witnessed by | Clifford |
Title of sampler | QA Inspector | Telephone number of sampler | 5103253065 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | AandM Nut and Bolt | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L78-003-19 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
---|---|---|---|
Heat Number(s) | 58033393 | Nut Mfg. Lot Number(s) | 6214745502 |
Washer Mfg. Lot Number(s) | 176421 | Bolt Specification | F1554 |
Bolt Length(s) | 40" | Nut Specification | A194 |
Washer Specification | F436 | Finish | GAL |
Diameter/Size | 1" | Bolt Mfg. Lot Number | 58033393 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2019-01-16-3
DIME Test ID: 2019-01-16-3-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2019-02-06
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 01/25/2019
UTM: 400KIP
Temperature: 72 F
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1B | 29370-6214745502 | 1-8 HEX | 108650 | 483.31 | Nut Proof | Brian |
General comments (publicly viewable) (Max 1000 characters): Nut Proof
Test Graph
Source: Partner Data Point FileTest was verified on 1/30/2019 ✔