Summary for Test 2018-11-07-5-1
Test performed: CALTRANS StdSpec-10Project Information
| Project Identifiers | DEA: No Project |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | 11/01/2022 |
| Work Description | Special project identifier for material not associated with a project |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 11/07/2018 | Sample Unique Key | 5 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/03/2018 |
| Sample type | Department Acceptance | A brief description of the sample | Cable yeild indicator assemblies |
| The quantity of what the sample constitutes | Unknown | From where was the sample collected | Source |
| First name of sampler or witnessed by | Greg | Last name of sampler or witnessed by | Thompson |
| Title of sampler | ASSOC STEEL INSP | Telephone number of sampler | 510-376-7155 |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Cable Moore | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B9-096-18 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | Cable Yield Indicator | Heat Number(s) | 166553 |
|---|---|---|---|
| Lot Number(s) | B9-096-18 | Lot Size(s) | 500 |
| Number of Samples | 8 |
Test Details
DIME Sample ID: 2018-11-07-5
DIME Test ID: 2018-11-07-5-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CALTRANS StdSpec-10: Section 75-1.03E(2)(b) Cable Yield Indicator (Cable Yield Indicator)
Test Release Date: 2018-12-21
Test Results
Input Type: Measured
Tester's full name: Fred
Date of test: 12/14/2018
UTM: 67kip
Test Temperature (F): 72 °F
Sample: 1
Lot: B909618
Height (in): no data
Inner Diameter (in): no data
Outer Diameter (in): no data
Peak Load (lbf): 36978 lbf
Halt of Force Yield (lbf): no data
Tested By: Fred
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest was verified on 12/14/2018 ✔