Summary for Test 2018-11-10-1-3
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 212573 DEA: 010B5504 EFIS: 0112000137 |
---|---|
DIST-CO-RTE-PM | 01-MEN-162-16.2 |
Award Date | 09/28/2017 |
Closeout Date | 10/05/2020 |
Work Description | RECONSTRUCT ROADWAY, CONSTRUCT SOLDIER PILE AND TIEBACK WALL |
Location Description | MENDOCINO COUNTY ON ROUTE 162 1 MILE EAST OF MIDDLE FORK EEL RIVER BRIDGE |
QA Service Level | 1 (Verified on 10/03/2017) |
Sample Information
Sample Taken Date | 11/10/2018 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/28/2018 |
Sample type | Quality Assurance | A brief description of the sample | Coupler |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Tom | Last name of sampler or witnessed by | Sayver |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | BarSplice CMC | Transportation Laboratory (TL) Number | C694524 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | CMC |
Coupler Manufacturer | BarSplice | Intermediate Assembler or Fabricator | Unknown |
Rebar Size | 5 | Coupler Model | Griptwist |
Coating Standards | ASTM A775 epoxy | Shape of Rebar | Straight |
Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
Coupler Component Heat/Lot Number(s) | A175856, 188143 | Rebar Heat Number(s) | 4078450 |
Rebar Size 2 | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2018-11-10-1
DIME Test ID: 2018-11-10-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2018-12-07
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 11/29/2018
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 3 | 1 | #5/16mm | 0.31 | 0 | 33054 | 106630 | Bar Broke, Ok Necking | Brian |
General comments (publicly viewable) (Max 1000 characters): Bar Broke, Ok Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 11/30/2018 ✔