Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2018-11-10-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 212573
DEA: 010B5504
EFIS: 0112000137
DIST-CO-RTE-PM01-MEN-162-16.2
Award Date09/28/2017
Closeout Date10/05/2020
Work DescriptionRECONSTRUCT ROADWAY, CONSTRUCT SOLDIER PILE AND TIEBACK WALL
Location DescriptionMENDOCINO COUNTY ON ROUTE 162 1 MILE EAST OF MIDDLE FORK EEL RIVER BRIDGE
QA Service Level1 (Verified on 10/03/2017)

Sample Information

Sample Taken Date11/10/2018 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/28/2018
Sample typeQuality Assurance A brief description of the sampleCoupler
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byTom Last name of sampler or witnessed bySayver
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameBarSplice CMC Transportation Laboratory (TL) NumberC694524
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC
Coupler ManufacturerBarSplice Intermediate Assembler or FabricatorUnknown
Rebar Size5 Coupler ModelGriptwist
Coating StandardsASTM A775 epoxy Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)A175856, 188143 Rebar Heat Number(s)4078450
Rebar Size 2 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2018-11-10-1-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory11/29/2018Brian
Yes
12/07/2018Bar Broke, Ok Necking
2018-11-10-1-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory11/29/2018Brian
Yes
12/07/2018Bar Broke, Ok Necking
2018-11-10-1-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory11/29/2018Brian
Yes
12/07/2018Bar Broke, Ok Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2018-11-10-1-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2018-11-10-1-2 CTM 670-December 2013 (Verified)