Summary for Test 2018-09-28-8-1
Test performed: ASTM A370-15Project Information
Project Identifiers | DEA: No Project |
---|---|
DIST-CO-RTE-PM | --- |
Award Date | Not set |
Closeout Date | 11/01/2022 |
Work Description | Special project identifier for material not associated with a project |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 09/28/2018 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/02/2018 |
Sample type | Quality Assurance | A brief description of the sample | Ductile Iron Casting |
The quantity of what the sample constitutes | 8 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Michelle | Last name of sampler or witnessed by | Haughey |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | SDI Farrar | Transportation Laboratory (TL) Number | NA |
Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM6 - Ductile Iron Cast Samples | Heat Number (s) | G118, G128, G138, G208, H028, H098, H098, H10 |
---|---|---|---|
Part Number (s) | 27 6 AH 27 6 PC BP 19 6 PCI BP 19 6 PC1 BP F | Material Specification | A536 |
Grades | 80-55-06 | Metal Foundry Manufacturer (Mill) | Farrar Corporation |
Prestressing Manufacturer | SDI |
Test Details
DIME Sample ID: 2018-09-28-8
DIME Test ID: 2018-09-28-8-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2018-10-17
Test Results
Number of Samples: 8
Input Type: Calculated
Tester's full name: Fred
Date of test: 10/05/2018
UTM: 67KIP
Temperature: 72 F
Num | Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | G118 | 0.501 | 0.1971 | 65040 | 114760 | 8.1 | Fred | |
2 | G128 | 0.501 | 0.1971 | 65065 | 113630 | 8.6 | Fred | |
3 | G138 | 0.501 | 0.1971 | 63093 | 107850 | 9.6 | Fred | |
4 | G208 | 0.5 | 0.1963 | 60831 | 105740 | 9.6 | Fred | |
5 | H028 | 0.501 | 0.1971 | 61512 | 106410 | 9.7 | Fred | |
6 | H098 | 0.5 | 0.1963 | 61500 | 107510 | 9.7 | Fred | |
7 | H098 | 0.501 | 0.1971 | 61675 | 105770 | 9.8 | Fred | |
8 | H108 | 0.501 | 0.1971 | 63463 | 111070 | 11 | Fred |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Test was verified on 10/10/2018 ✔