Summary for Test 2018-07-19-14-1

Test performed: ASME B1.2-83r01

Project Information

Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Award DateNot set
Closeout Date11/01/2022
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date07/19/2018 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/19/2018
Sample typeQuality Assurance A brief description of the sample2, 2-1/4 A563 nuts
The quantity of what the sample constitutes5 from each lot From where was the sample collectedDistributor
First name of sampler or witnessed byPrescott Last name of sampler or witnessed byLeavitt
Title of samplerQA Inspector Telephone number of sampler5105900116
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameUniversal Industrial Sales Dyson Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormS28-193-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)N/A
Heat Number(s)188194, 166581, 188539 Nut Mfg. Lot Number(s)DDYO, DDWH, DDYZ
Washer Mfg. Lot Number(s)N/A Bolt SpecificationN/A
Bolt Length(s)N/A Nut SpecificationA563-DH
Washer SpecificationN/A FinishPlain, Plain, HDG
Diameter/Size2, 2-1/4, 2-1/4 Bolt Mfg. Lot NumberN/A
Rocap Test Requirement(s)No Lubricant Requirements(s)No, No, Yes

Test Details

DIME Sample ID: 2018-07-19-14
DIME Test ID: 2018-07-19-14-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Test Release Date: 2018-08-13

Test Results


Input Type: Calculated
Tester's full name: Brian Ewing
Date of test: 07/30/2018
Sample No.: 1A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: DDYO
Finish Coating: Plain
Product Markings: 2H DH D/N
Size: 2 in
Gage Type: Pass
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/6/2018