Summary for Test 2018-06-22-3-2
Test performed: ASTM A416-15Project Information
Project Identifiers | DEA: No Project |
---|---|
DIST-CO-RTE-PM | --- |
Award Date | Not set |
Closeout Date | 11/01/2022 |
Work Description | Special project identifier for material not associated with a project |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 06/22/2018 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/05/2018 |
Sample type | Quality Assurance | A brief description of the sample | .6 inch Prestress strand |
The quantity of what the sample constitutes | 6 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Jim | Last name of sampler or witnessed by | Hoenig |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Insteel Wire Stressteel | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM4 - Prestressing Strand | Comments | full lot numbers on paperwork |
---|---|---|---|
Reel/Coil/Pack Number(s) | Number of Coils | Unknown | |
Group Number | Unknown | Strand Diameter | |
Grade | 270 | Strand Specification | ASTM A 416 |
Heat Number(s) | 18102223 | Mfg. Lot Number(s) | 614, 617, 620, 639, 616, 638 |
Manufacturer(s) | Insteel |
Test Details
DIME Sample ID: 2018-06-22-3
DIME Test ID: 2018-06-22-3-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2018-07-18
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 07/10/2018
UTM: 120KIP
Temperature: 72 F
Extensometers: E88768
Num | Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 18102223 | 1302468171638 | 0.218 | 60063 | 54373 | 28.4 | 1.82 | Brian |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 7/11/2018 ✔