Summary for Test 2018-04-06-2-3

Test performed: ASTM F606-14a

Project Information

Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Award DateNot set
Closeout Date11/01/2022
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date04/06/2018 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/11/2018
Sample typeQuality Assurance A brief description of the sampleF1554 Anchor Rods Nuts Washers
The quantity of what the sample constitutes3 From where was the sample collectedSource
First name of sampler or witnessed byJames Last name of sampler or witnessed byShelton
Title of samplerCALTRANS METS QA INSPECTOR Telephone number of sampler530 906 2714
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameA and M Nut and Bolt Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormS40-019-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)3066884 Nut Mfg. Lot Number(s)26581-75067329
Washer Mfg. Lot Number(s)0417-513 Bolt SpecificationF1554 Gr.55-S1
Bolt Length(s)12" Nut SpecificationA194 Gr. 2H
Washer SpecificationF436 FinishHDG
Diameter/Size5/8 Bolt Mfg. Lot Number41693-PPO
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2018-04-06-2
DIME Test ID: 2018-04-06-2-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2018-04-20

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 04/13/2018
UTM: 400KIP
Temperature: 72 F
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11B26581-750673295/8-11 Hex40192178.78Nut Proof LoadBrian

General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point File

Test was verified on 4/13/2018