Summary for Test 2017-08-25-3-18
Test performed: ASTM B499-14Project Information
Project Identifiers | Project ID: 212164 DEA: 051J1304 EFIS: 0517000064 |
---|---|
DIST-CO-RTE-PM | 05-MON,MON-1-45.52, 45.4/45.8 |
Award Date | 02/16/2017 |
Closeout Date | 10/25/2019 |
Work Description | Pfeiffer Canyon Emergency Bridge Replacement Project |
Location Description | Highway 1 at Pfeiffer State Park |
QA Service Level | 1 (Verified on 02/27/2017) |
Sample Information
Sample Taken Date | 08/25/2017 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/28/2017 |
Sample type | Quality Assurance | A brief description of the sample | A325 HDG Rocap Assembiy |
The quantity of what the sample constitutes | 5 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Jeff | Last name of sampler or witnessed by | Smith |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Golden State Bridge | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B7-382-17 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | L1412301 |
---|---|---|---|
Heat Number(s) | 62143690 | Nut Mfg. Lot Number(s) | 25479-75064716 |
Washer Mfg. Lot Number(s) | C6495D | Bolt Specification | A325 |
Bolt Length(s) | 8.75" | Nut Specification | A563 |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | 1" | Bolt Mfg. Lot Number | 322399 |
Rocap Test Requirement(s) | Lubricant Requirements(s) | Yes |
Test Details
DIME Sample ID: 2017-08-25-3
DIME Test ID: 2017-08-25-3-18
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2017-09-04
Test Results
Input Type: Calculated
Tester's full name: Brian Ewing
Date of test: 08/28/2017
Sample No.: 1D
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 322399
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: BB A325
Size: 1 in
Bolt Length: 8.75 in
Measurement Average: 3.86 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/28/2017 ✔