Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2017-08-25-3
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 212164 DEA: 051J1304 EFIS: 0517000064 |
---|---|
DIST-CO-RTE-PM | 05-MON,MON-1-45.52, 45.4/45.8 |
Award Date | 02/16/2017 |
Closeout Date | 10/25/2019 |
Work Description | Pfeiffer Canyon Emergency Bridge Replacement Project |
Location Description | Highway 1 at Pfeiffer State Park |
QA Service Level | 1 (Verified on 02/27/2017) |
Sample Information
Sample Taken Date | 08/25/2017 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/28/2017 |
Sample type | Quality Assurance | A brief description of the sample | A325 HDG Rocap Assembiy |
The quantity of what the sample constitutes | 5 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Jeff | Last name of sampler or witnessed by | Smith |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Golden State Bridge | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B7-382-17 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | L1412301 |
---|---|---|---|
Heat Number(s) | 62143690 | Nut Mfg. Lot Number(s) | 25479-75064716 |
Washer Mfg. Lot Number(s) | C6495D | Bolt Specification | A325 |
Bolt Length(s) | 8.75" | Nut Specification | A563 |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | 1" | Bolt Mfg. Lot Number | 322399 |
Rocap Test Requirement(s) | Lubricant Requirements(s) | Yes |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2017-08-25-3-1 ASTM F606-14a (Verified)
DIME Test ID: 2017-08-25-3-2 ASTM F606-14a (Verified)
DIME Test ID: 2017-08-25-3-3 ASTM F606-14a (Verified)
DIME Test ID: 2017-08-25-3-4 ASTM F606-14a (Verified)
DIME Test ID: 2017-08-25-3-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-08-25-3-6 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-08-25-3-7 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-08-25-3-8 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-08-25-3-9 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-08-25-3-10 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-08-25-3-11 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-08-25-3-12 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-08-25-3-13 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-08-25-3-14 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-08-25-3-15 ASTM B499-14 (Verified)
DIME Test ID: 2017-08-25-3-16 ASTM B499-14 (Verified)
DIME Test ID: 2017-08-25-3-17 ASTM B499-14 (Verified)
DIME Test ID: 2017-08-25-3-18 ASTM B499-14 (Verified)
DIME Test ID: 2017-08-25-3-19 ASTM B499-14 (Verified)
DIME Test ID: 2017-08-25-3-20 ASTM B499-14 (Verified)
DIME Test ID: 2017-08-25-3-21 ASTM B499-14 (Verified)
DIME Test ID: 2017-08-25-3-22 ASTM B499-14 (Verified)
DIME Test ID: 2017-08-25-3-23 ASTM B499-14 (Verified)
DIME Test ID: 2017-08-25-3-24 ASTM B499-14 (Verified)
DIME Test ID: 2017-08-25-3-25 ASTM B499-14 (Verified)
DIME Test ID: 2017-08-25-3-26 ASTM B499-14 (Verified)
DIME Test ID: 2017-08-25-3-27 ASTM B499-14 (Verified)
DIME Test ID: 2017-08-25-3-28 ASTM B499-14 (Verified)
DIME Test ID: 2017-08-25-3-29 ASTM B499-14 (Verified)
DIME Test ID: 2017-08-25-3-30 ASTM E18-15 (Verified)
DIME Test ID: 2017-08-25-3-31 ASTM E18-15 (Verified)