Summary for Test 2017-07-31-3-2
Test performed: ASTM F606-14Project Information
Project Identifiers | Project ID: 211800 DEA: 09356104 EFIS: 0912000044 |
---|---|
DIST-CO-RTE-PM | 09-MNO-395-34.1 |
Award Date | 01/31/2017 |
Closeout Date | 11/12/2019 |
Work Description | CONSTRUCT MAINTENANCE EQUIPMENT STORAGE BUILDING AND SITE WORK. |
Location Description | BUILDING CONSTRUCTION ADJACENT TO STATE HIGHWAY IN MONO COUNTY AT CRESTVIEW AT THE CRESTVIEW SATELLITE MAINTENANCE STATION |
QA Service Level | 1 (Verified on 06/01/2017) |
Sample Information
Sample Taken Date | 07/31/2017 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/01/2017 |
Sample type | Quality Assurance | A brief description of the sample | 5/8 inch ATR |
The quantity of what the sample constitutes | 1 lot of 8 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Stacey | Last name of sampler or witnessed by | Davis |
Title of sampler | QAI | Telephone number of sampler | 5624806984 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Portland Bolt | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
---|---|---|---|
Heat Number(s) | PL15107101 | Nut Mfg. Lot Number(s) | 24293-75064046 |
Washer Mfg. Lot Number(s) | N/A | Bolt Specification | A1554, grade 36 |
Bolt Length(s) | 4" | Nut Specification | A563, grade DH |
Washer Specification | not required | Finish | HDG |
Diameter/Size | 5/8 | Bolt Mfg. Lot Number | N/A |
Rocap Test Requirement(s) | Lubricant Requirements(s) | none |
Test Details
DIME Sample ID: 2017-07-31-3
DIME Test ID: 2017-07-31-3-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2017-08-11
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 08/04/2017
UTM: 400KIP
Temperature: 72
Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
---|---|---|---|---|---|---|---|---|---|
1 | 1B | F1554 5/8\" x 4 Stud w/ Nut | 0.226 | 18513 | 82 | 81916 | 71607 | 16183 | F1554 Stud & Nut |
General comments (publicly viewable) (Max 1000 characters): F1554 Stud & Nut
Test Graph
Source: Partner Data Point FileTest was verified on 8/4/2017 ✔