Summary for Test 2017-07-13-5-3
Test performed: ASTM A934-13Project Information
Project Identifiers | Project ID: 211931 DEA: 043G6414 EFIS: 0416000348 |
---|---|
DIST-CO-RTE-PM | 04-NAP-29-37.0 |
Award Date | 03/17/2017 |
Closeout Date | 04/22/2020 |
Work Description | SCOUR REPLACE BRIDGE |
Location Description | NAPA COUNTY IN CALISTOGA AT NAPA RIVER BRIDGE |
QA Service Level | 1 (Verified on 02/15/2017) |
Sample Information
Sample Taken Date | 07/13/2017 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/17/2017 |
Sample type | Quality Assurance | A brief description of the sample | Williams Thread Bars |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Chris | Last name of sampler or witnessed by | Moulton |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Williams Forms | Transportation Laboratory (TL) Number | C647232 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L7300517 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Production Testing |
---|---|---|---|
Threaded Bar Specification | ASTM A615 | Threaded Bar Grade | 75 |
Threaded Bar Type | Deformed | Rebar Size | #9 |
Nut Specification for Threaded Bar | 75 | System Manufacturer | Williams Form |
Epoxy Coating Color | Purple | Threaded Bar Application | Threaded Bar |
Coating Standards | ASTM A934 epoxy | Bar Heat Number(s) | 100786966 |
Nut Heat Number(s) | 9H5D | Bar Lot Number | Unknown |
Nut Lot Number | Unknown | Coupler Heat Number(s) | 9H2D |
Coupler Grade | 75 |
Test Details
DIME Sample ID: 2017-07-13-5
DIME Test ID: 2017-07-13-5-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)
Test Release Date: 2017-07-27
Test Results
Input Type: Measured
Tester's full name: Fred Saylor
Date of test: 07/19/2017
Lower spec. limit LSL: 10 mils
Upper spec. limit USL: 15 mils
Bar # for First Bar: 1
Bar # for Second Bar: 2
First Bar Side 1 mean value: 9.568 mils
First Bar Side 2 mean value: 9.636 mils
Second Bar Side 1 mean value: 9.103 mils
Second Bar Side 2 mean value: 9.49 mils
First Bar Mean: 9.6 mils
Second Bar Mean: 9.3 mils
Total mean value: 9.45 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/20/2017 ✔