Summary for Test 2017-06-27-2-2
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 211004 DEA: 05330784 EFIS: 0512000076 |
---|---|
DIST-CO-RTE-PM | 05-SLO-46-46.0/50.2 |
Award Date | 02/10/2016 |
Closeout Date | 10/15/2019 |
Work Description | CONVERT 2-LANE TO 4 LANE EXPRESSWAY. |
Location Description | NEAR SHANDON FROM 0.2 MILE EAST OF MCMILLIAN CANYON ROAD TO 0.4 MILE WEST OF LUCY BROWN ROAD |
QA Service Level | 1 (Verified on 01/08/2016) |
Sample Information
Sample Taken Date | 06/27/2017 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/27/2017 |
Sample type | Verification | A brief description of the sample | 7/8 x 16 A449 anchor bolt assembly |
The quantity of what the sample constitutes | 3 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Flygare |
Title of sampler | CA METS QA Inspector | Telephone number of sampler | 801-669-2984 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | UIS | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B76-074-17 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | none |
---|---|---|---|
Heat Number(s) | Bolt 166726, washer 41542750, nut10432280 | Nut Mfg. Lot Number(s) | Decker 16-40-005 |
Washer Mfg. Lot Number(s) | Prestige D2181 | Bolt Specification | A449 |
Bolt Length(s) | 16" | Nut Specification | A563-DH |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | 7/8 | Bolt Mfg. Lot Number | Rockford 29391 |
Rocap Test Requirement(s) | none | Lubricant Requirements(s) | none |
Test Details
DIME Sample ID: 2017-06-27-2
DIME Test ID: 2017-06-27-2-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2017-07-19
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 07/07/2017
UTM: 400KIP
Temperature: 71 F
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1A | B76-074-17 | 7/8\" | 71025 | 315.94 | Nut Proof Load | Brian |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point FileTest was verified on 7/12/2017 ✔