Sample Record

Owner Lab

  • CT HQ - QASI Bay Area Field Office

DIME Sample ID 2017-06-27-2

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211004
DEA: 05330784
EFIS: 0512000076
DIST-CO-RTE-PM05-SLO-46-46.0/50.2
Award Date02/10/2016
Closeout Date10/15/2019
Work DescriptionCONVERT 2-LANE TO 4 LANE EXPRESSWAY.
Location DescriptionNEAR SHANDON FROM 0.2 MILE EAST OF MCMILLIAN CANYON ROAD TO 0.4 MILE WEST OF LUCY BROWN ROAD
QA Service Level1 (Verified on 01/08/2016)

Sample Information

Sample Taken Date06/27/2017 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/27/2017
Sample typeVerification A brief description of the sample7/8 x 16 A449 anchor bolt assembly
The quantity of what the sample constitutes3 From where was the sample collectedFabricator
First name of sampler or witnessed byDavid Last name of sampler or witnessed byFlygare
Title of samplerCA METS QA Inspector Telephone number of sampler801-669-2984
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameUIS Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormB76-074-17 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)none
Heat Number(s)Bolt 166726, washer 41542750, nut10432280 Nut Mfg. Lot Number(s)Decker 16-40-005
Washer Mfg. Lot Number(s)Prestige D2181 Bolt SpecificationA449
Bolt Length(s)16" Nut SpecificationA563-DH
Washer SpecificationF436 FinishHDG
Diameter/Size7/8 Bolt Mfg. Lot NumberRockford 29391
Rocap Test Requirement(s)none Lubricant Requirements(s)none

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-06-27-2-1ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory07/07/2017Brian
Yes
07/19/2017A449 Bolt
2017-06-27-2-2ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory07/07/2017Brian
Yes
07/19/2017Nut Proof Load
2017-06-27-2-3ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory07/07/2017Brian
Yes
07/19/2017Nut Proof Load
2017-06-27-2-4ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/11/2017Brian Ewing
Yes
07/19/2017
2017-06-27-2-5ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/11/2017Brian Ewing
Yes
07/19/2017
2017-06-27-2-6ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/11/2017Brian Ewing
Yes
07/19/2017
2017-06-27-2-7ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/11/2017Brian Ewing
Yes
07/19/2017
2017-06-27-2-8ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/11/2017Brian Ewing
Yes
07/19/2017
2017-06-27-2-9ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/11/2017Brian Ewing
Yes
07/19/2017
2017-06-27-2-10ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory07/11/2017Brian Ewing
Yes
07/19/2017

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-06-27-2-1 ASTM F606-14 (Verified)
DIME Test ID: 2017-06-27-2-2 ASTM F606-14a (Verified)
DIME Test ID: 2017-06-27-2-3 ASTM F606-14a (Verified)
DIME Test ID: 2017-06-27-2-4 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-06-27-2-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-06-27-2-6 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-06-27-2-7 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-06-27-2-8 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-06-27-2-9 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-06-27-2-10 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-06-27-2-11 ASME B1.2-83r01 (Verified)
DIME Test ID: 2017-06-27-2-12 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-27-2-13 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-27-2-14 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-27-2-15 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-27-2-16 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-27-2-17 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-27-2-18 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-27-2-19 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-27-2-20 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-27-2-21 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-27-2-22 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-27-2-23 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-27-2-24 ASTM B499-14 (Verified)
DIME Test ID: 2017-06-27-2-25 ASTM E18-15 (Verified)
DIME Test ID: 2017-06-27-2-26 ASTM E18-15 (Verified)
DIME Test ID: 2017-06-27-2-27 ASTM E18-15 (Verified)