Summary for Test 2024-03-29-46-6
Test performed: CTM 521-June 2020Project Information
Project Identifiers | Project ID: 994116 DEA: 010J4104 EFIS: 0119000025 |
---|---|
DIST-CO-RTE-PM | 01-HUM-299-30.7/33.4 |
Award Date | 11/23/2022 |
Closeout Date | Not set |
Work Description | Project Name: HUM-299 Curve Improvement |
Location Description | HUMBOLDT COUNTY NEAR WILLOW CREEK FROM 0.1 MILE EAST OF CEDAR CREEK ROAD TO 0.1 MILE EAST OF EAST FORK WILLOW CREEK BRIDGE |
QA Service Level | 1 (Verified on 07/29/2022) |
Sample Information
Sample Taken Date | 03/29/2024 | Sample Unique Key | 46 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/29/2024 |
Sample type | Quality Assurance | A brief description of the sample | PCC |
The quantity of what the sample constitutes | 3 Cy | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Joe | Last name of sampler or witnessed by | Aufdermaur |
Title of sampler | Special Inspector | Telephone number of sampler | 707-441-8855 |
Laboratory sample identification | C9133 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Eureka Ready mix | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | E67538WRF |
---|---|---|---|
The truck number from where the sample was collected | 93 | The batch plant ticket number from where the sample was collected | 35014 |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | Concrete sample from wheelbarrow | Where the material sample would have been placed if not sampled | Test Panel |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2024-03-29-46
DIME Test ID: 2024-03-29-46-6
Testing Lab: SHN Engineers & Geologists, Inc.
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-04-26
Test Results
Unit system used?: US Units
Number of specimens: 5
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Dave Gonzales
Date of test: 04/26/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Average diameter of cylinder 4: 4.00 in
Average diameter of cylinder 5: 4.00 in
Maximum load on cylinder 1: 65160 lb
Maximum load on cylinder 2: 65340 lb
Maximum load on cylinder 3: 68100 lb
Maximum load on cylinder 4: 63380 lb
Maximum load on cylinder 5: 66280 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 2
Type of fracture pattern of cylinder 4: 3
Type of fracture pattern of cylinder 5: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Correction factor for cylinder 3: 1
Correction factor for cylinder 4: 1
Correction factor for cylinder 5: 1
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Cross sectional area of cylinder 4: 12.57 in^2
Cross sectional area of cylinder 5: 12.57 in^2
Compressive strength (to nearest 10 psi): 5270 psi
General comments (publicly viewable) (Max 1000 characters): Performed ASTM C39
Test was verified on 4/26/2024 ✔