Summary for Test 2024-03-29-1-1
Test performed: ASTM A934-19Project Information
Project Identifiers | Project ID: 994588 DEA: 081H3904 EFIS: 0817000032 |
---|---|
DIST-CO-RTE-PM | 08-SBD-15-R20.5/R21.6,R25.5/R30.7 |
Award Date | 07/13/2023 |
Closeout Date | Not set |
Work Description | CONSTRUCT BUILDING, ROADWAY EXC, JPCP, AND TEMPORARY BARRIER SYSTEM. |
Location Description | SAN BERNARDINO COUNTY FROM 0.6 MILE NORTH OF CLEGHORN ROAD UNDERCROSSING TO 0.5 MILE SOUTH OF ROUTE 138 AND FROM 0.5 MILE SOUTH OF TRUCK SAFETY CHECK AREA TO 0.4 MILE NORTH OF OAK HILL ROAD OVERCROSSING |
QA Service Level | 1 (Verified on 08/02/2023) |
Sample Information
Sample Taken Date | 03/29/2024 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/03/2024 |
Sample type | Quality Assurance | A brief description of the sample | #8 GR75 All Thread Bar Epoxy Coated |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Adrian | Last name of sampler or witnessed by | Sanchez |
Title of sampler | Telephone number of sampler | 2137133499 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | WFE SD | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L159-052-24 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Production Testing |
---|---|---|---|
Threaded Bar Specification | ASTM A615 | Threaded Bar Grade | 75 |
Threaded Bar Type | Deformed | Rebar Size | |
Nut Specification for Threaded Bar | 29 | System Manufacturer | Drill Tech |
Epoxy Coating Color | Purple | Threaded Bar Application | Threaded Bar |
Coating Standards | ASTM A934 epoxy | Bar Heat Number(s) | 1000123050 |
Nut Heat Number(s) | 5395778 | Bar Lot Number | |
Nut Lot Number | Coupler Heat Number(s) | ||
Coupler Grade |
Test Details
DIME Sample ID: 2024-03-29-1
DIME Test ID: 2024-03-29-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A934-19: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)
Test Release Date: 2024-04-19
Test Results
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 04/17/2024
Lower spec. limit LSL: 10 mils
Upper spec. limit USL: 15 mils
Bar # for First Bar: 1
Bar # for Second Bar: 2
First Bar Side 1 mean value: 10.08
First Bar Side 2 mean value: 10.03
Second Bar Side 1 mean value: 10.13
Second Bar Side 2 mean value: 10.03
First Bar Mean: 10.06
Second Bar Mean: 10.08
Total mean value: 10.07
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/19/2024 ✔