Summary for Test 2024-02-29-19-3

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 994109
DEA: 060W1704
EFIS: 0617000103
DIST-CO-RTE-PM06-FRE-41-R27.4/R28.5
Award Date11/10/2022
Closeout DateNot set
Work DescriptionREMOVE AC PAVEMENT, WIDEN TRAVEL WAY, AND CONSTRUCT RETAINING WALL.
Location DescriptionFRESNO COUNTY IN FRESNO FROM 0.1 MILE SOUTH OF ASHLAN AVENUE OVERCROSSING TO SHAW AVENUE OVERCROSSING
QA Service Level1 (Verified on 07/13/2022)

Sample Information

Sample Taken Date02/29/2024 Sample Unique Key19
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/01/2024
Sample typeDepartment Acceptance A brief description of the sample7.18sk 1AGG FA WD
The quantity of what the sample constitutes123.5cy From where was the sample collectedJob Site
First name of sampler or witnessed byGerzon Last name of sampler or witnessed byCeja
Title of samplerASR Telephone number of sampler5599172487
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameBuilders Concrete Ready Mix Plant Sanger Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameHwy 41 AUX LANE

Material Information

Material TypeConcrete The concrete mix design numberND22023
The truck number from where the sample was collected9227 The batch plant ticket number from where the sample was collected111338179
Concrete batch plantBuilders Concrete The fabricator/manufacturer designation for the sampleMix
A detailed description of where the material sample was collectedwheelbarrow Where the material sample would have been placed if not sampledRetaining wall
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-02-29-19
DIME Test ID: 2024-02-29-19-3
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-03-28

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Tomas Silva
Date of test: 03/28/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.01 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.01 in
Maximum load on cylinder 1: 89110 lb
Maximum load on cylinder 2: 85780 lb
Maximum load on cylinder 3: 88740 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Correction factor for cylinder 3: 1
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.63 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.63 in^2
Compressive strength of cylinder 1: 7055.4 psi
Compressive strength of cylinder 2: 6824.2 psi
Compressive strength of cylinder 3: 7026.1 psi
Compressive strength (to nearest 10 psi): 6970 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/28/2024