Summary for Test 2023-11-30-1-7
Test performed: ASTM F606-21Project Information
Project Identifiers | Project ID: 212112 DEA: 080C2514 EFIS: 0816000076 COOP: 081645 |
---|---|
DIST-CO-RTE-PM | 08-SBD-10-0.0/13.2 |
Award Date | 06/06/2018 |
Closeout Date | Not set |
Work Description | Design-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes |
Location Description | LA/SBD County Line to PM 13.2 near I-15 |
QA Service Level | 1 (Verified on 10/16/2019) |
Sample Information
Sample Taken Date | 11/30/2023 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/03/2024 |
Sample type | Quality Assurance | A brief description of the sample | 3/4 A325 Bolts |
The quantity of what the sample constitutes | 1 Lot of 15ea. | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Osiel | Last name of sampler or witnessed by | Ramirez |
Title of sampler | Quality Assurance Inspector | Telephone number of sampler | 9167673535 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Craneveyor Corp | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L123-127-23 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 1000118728, DL20101939, A74827 | Nut Mfg. Lot Number(s) | Nucor Steel #443780A |
Washer Mfg. Lot Number(s) | Binder Metal Products lot #169943 | Bolt Specification | A325 |
Bolt Length(s) | 2 1/2" | Nut Specification | ASTM A563 |
Washer Specification | ASTM F436 | Finish | A325 HDG |
Diameter/Size | 3/4 Dia | Bolt Mfg. Lot Number | Nucor Steel #W000035472 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2023-11-30-1
DIME Test ID: 2023-11-30-1-7
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2024-01-04
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 12/13/2023
UTM: 450kip
Temperature: 72 f
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1A | 54749 | Proof Load |
General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 1/4/2024 ✔