Summary for Test 2023-12-13-33-1
Test performed: ASTM C39-21Project Information
Project Identifiers | Project ID: 214590 DEA: 043G4744 EFIS: 0412000074 |
---|---|
DIST-CO-RTE-PM | 04-MRN,MRN-580-6.9/7.8,0.0/2.5 |
Award Date | 01/14/2021 |
Closeout Date | Not set |
Work Description | CLEAN AND PAINT STRUCTURAL STEEL BRIDGE. |
Location Description | CONTRA COSTA AND MARIN COUNTIES IN RICHMOND AND SAN RAFAEL FROM 0.8 MILE WEST OF TOLL PLAZA TO 0.1 MILE EAST OF MAIN STREET |
QA Service Level | 1 (Verified on 02/18/2020) |
Sample Information
Sample Taken Date | 12/13/2023 | Sample Unique Key | 33 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 12/20/2023 |
Sample type | Quality Assurance | A brief description of the sample | 4x8 concrete cylinders |
The quantity of what the sample constitutes | 4.5 CY | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Quetzal | Last name of sampler or witnessed by | Cornejo Molina |
Title of sampler | ASR | Telephone number of sampler | (510) 867-6015 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | American Civil Constructors | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | 28-0100 | |
Structure name | Richmond-San Rafael Bridge |
Material Information
Material Type | Concrete | The concrete mix design number | 21005-12 |
---|---|---|---|
The truck number from where the sample was collected | Load 2 | The batch plant ticket number from where the sample was collected | Slip 86 |
Concrete batch plant | VOLUMETRIC TRUCK | The fabricator/manufacturer designation for the sample | Batch |
A detailed description of where the material sample was collected | collected from chute to Wheel Barrow | Where the material sample would have been placed if not sampled | Pier 55 Expansion Joint |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2023-12-13-33
DIME Test ID: 2023-12-13-33-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2023-12-20
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: SA
Date of test: 12/20/2023
Apparent mass of submerged cylinder 1: no data
Average diameter of cylinder 1: 4.02 in
Average diameter of cylinder 2: 4.01 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 69489 lbf
Maximum load on cylinder 2: 82158 lbf
Maximum load on cylinder 3: 77401 lbf
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 1
Type of fracture pattern of cylinder 3: 4
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 7 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 12.69 in^2
Cross sectional area of cylinder 2: 12.63 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 5475.0 psi
Compressive strength of cylinder 2: 6505.0 psi
Compressive strength of cylinder 3: 6159 psi
Compressive strength (to nearest 10 psi): 6050 psi
Serial number of delivery ticket, if available: no data
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point FileTest graph for Cylinder Code 1 of 3
Source: Bluehill Data Point File
Test graph for Cylinder Code 2 of 3
Source: Bluehill Data Point File
Test graph for Cylinder Code 3 of 3
Test was verified on 12/20/2023 ✔