Summary for Test 2023-11-27-26-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 212112 DEA: 080C2514 EFIS: 0816000076 COOP: 081645 |
---|---|
DIST-CO-RTE-PM | 08-SBD-10-0.0/13.2 |
Award Date | 06/06/2018 |
Closeout Date | Not set |
Work Description | Design-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes |
Location Description | LA/SBD County Line to PM 13.2 near I-15 |
QA Service Level | 1 (Verified on 10/16/2019) |
Sample Information
Sample Taken Date | 11/27/2023 | Sample Unique Key | 26 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/05/2023 |
Sample type | Department Acceptance | A brief description of the sample | 3/4" HMA-A-SP R15 0.50% LAS |
The quantity of what the sample constitutes | 1 BOX OF HMA | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Vulcan | Last name of sampler or witnessed by | Vulcan QC |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0605A-23 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | VULCAN-CORONA DRUM | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | 224112 CORD SJR |
Test Details
DIME Sample ID: 2023-11-27-26
DIME Test ID: 2023-11-27-26-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-12-12
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Dylan Nault
Date of test: 12/08/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2143.5 g
Mass Loss: 106.5 g
Correction Factor (Percent by mass of HMA Specimen): 0.56 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.07 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.34 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/12/2023 ✔