Summary for Test 2017-04-14-3-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 211794
DEA: 044G5104
EFIS: 0412000483
DIST-CO-RTE-PM04-SOL-80-31.4,32.6
Award Date01/20/2017
Closeout Date09/12/2019
Work DescriptionBRIDGE CONSTRUCTION
Location DescriptionSOLANO COUNTY IN AND NEAR VACAVILLE AT MERIDIAN ROAD OVERCROSSING AND AT MIDWAY ROAD OVERCROSSING
QA Service Level1 (Verified on 01/03/2017)

Sample Information

Sample Taken Date04/14/2017 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/18/2017
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes4 From where was the sample collectedManufacturer
First name of sampler or witnessed byGary Last name of sampler or witnessed byMaComb
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCMC Rebar Transportation Laboratory (TL) NumberC970931
Inspector Lot Number from the Transportation Laboratory (TL) FormL1003717 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4065065
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size7
Diameter of Hoop4'-7" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Rebar
Welding CompanyCMC Rebar (Etiwanda) Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2017-04-14-3
DIME Test ID: 2017-04-14-3-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2017-04-25

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 04/18/2017
UTM: 2000KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
131#7/22mm0.65624093730Bar BrokeFred

General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 4/18/2017