Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2017-04-14-3

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211794
DEA: 044G5104
EFIS: 0412000483
DIST-CO-RTE-PM04-SOL-80-31.4,32.6
Award Date01/20/2017
Closeout Date09/12/2019
Work DescriptionBRIDGE CONSTRUCTION
Location DescriptionSOLANO COUNTY IN AND NEAR VACAVILLE AT MERIDIAN ROAD OVERCROSSING AND AT MIDWAY ROAD OVERCROSSING
QA Service Level1 (Verified on 01/03/2017)

Sample Information

Sample Taken Date04/14/2017 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/18/2017
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes4 From where was the sample collectedManufacturer
First name of sampler or witnessed byGary Last name of sampler or witnessed byMaComb
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCMC Rebar Transportation Laboratory (TL) NumberC970931
Inspector Lot Number from the Transportation Laboratory (TL) FormL1003717 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4065065
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size7
Diameter of Hoop4'-7" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Rebar
Welding CompanyCMC Rebar (Etiwanda) Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-04-14-3-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory04/18/2017Fred
Yes
04/25/2017Bar Broke; OK Necking
2017-04-14-3-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory04/18/2017Fred
Yes
04/25/2017Bar Broke; OK Necking
2017-04-14-3-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory04/18/2017Fred
Yes
04/25/2017Bar Broke; OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-04-14-3-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-04-14-3-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2017-04-14-3-3 CTM 670-December 2013 (Verified)