Summary for Test 2023-07-19-50-5

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 993629
DEA: 112N0874
EFIS: 1119000220
DIST-CO-RTE-PM11-SD-5,15,76,78-Var
Award Date05/27/2022
Closeout Date02/27/2024
Work DescriptionPPLY METHACRYLATE, PLACE POLYESTER CONCRETE OVERLAY Apply Methacrylate on bridge deck
Location DescriptionSAN DIEGO COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 03/21/2022)

Sample Information

Sample Taken Date07/19/2023 Sample Unique Key50
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/20/2023
Sample typeQuality Assurance A brief description of the sample1/2" HMA
The quantity of what the sample constitutes8 boxes 3 bags From where was the sample collectedSource
First name of sampler or witnessed byJesse Last name of sampler or witnessed byFuentes
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Otay Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number320819 Otay Val

Test Details

DIME Sample ID: 2023-07-19-50
DIME Test ID: 2023-07-19-50-5
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-09-01

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Melchor Oronoz
Date of test: 08/18/2023
Test procedure used?: Method A
Mass of the specimen basket assembly: 3926.4 g
Mass of the specimen and specimen basket assembly prior to ignition: 5465.6 g
Mass of HMA Sample prior to ignition: 1539.2 g
Mass Loss: 102.9 g
Mass of aggregate remaining after ignition: 1436.3 g
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 F
Corrected Asphalt Binder Content: 6.69 %
General comments (publicly viewable) (Max 1000 characters): RAP

Test was verified on 9/1/2023