Summary for Test 2023-07-11-27-2

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 215109
DEA: 081C8504
EFIS: 0813000047
DIST-CO-RTE-PM08-RIV-74-0.0/5.8
Award DateNot set
Closeout DateNot set
Work DescriptionROADWAY EXCAVATION, HOT MIX ASPHALT, AND STRUCTURAL SHOTCRETE WALLS.
Location DescriptionRIVERSIDE COUNTY NEAR LAKE ELSINORE FROM ORANGE COUNTY LINE TO MONTE VISTA STREET
QA Service Level1 (Verified on 02/24/2021)

Sample Information

Sample Taken Date07/11/2023 Sample Unique Key27
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/14/2023
Sample typeVerification A brief description of the samplePSUE 3/4" HMA-A-SP R25 0.5% LAS
The quantity of what the sample constitutes3 Bags Of Agg., 1 Bag Rap From where was the sample collectedManufacturer
First name of sampler or witnessed byMartin Last name of sampler or witnessed byMarietta QC
Title of sampler Telephone number of sampler
Laboratory sample identification0366A-23 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCCA- Lake Elsinore Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0098
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt Cut At CCA-Lake Elsinore
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number53417615FR Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-07-11-27
DIME Test ID: 2023-07-11-27-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2023-10-04

Test Results


Input Type: Measured
Tester's full name: Friday Ofoegbu
Date of test: 07/20/2023
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 962.5 grams
Mass of the pycnometer with water (B): 653.4 grams
Mass of the oven dried sample (before pycnometer) (A): 494 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 494 grams
Test Sample Preparation: 6% Moisture
Bulk specific gravity: 2.588
Bulk specific gravity (SSD Basis): 2.619
Apparent specific gravity: 2.672
Absorption: 1.2 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/4/2023