Summary for Test 2023-08-07-5-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 213749
DEA: 120C1104
EFIS: 1200000633
DIST-CO-RTE-PM12-ORA-57-20.3/21.6
Award Date04/19/2019
Closeout DateNot set
Work DescriptionSR-57 Lambert Interchange Project: WIDEN BRIDGES AND CONSTRUCT RW, SW, HMA, JPCP AND ELECTRICAL SYSTEMS.
Location DescriptionORANGE COUNTY IN BREA FROM 0.6 MILE SOUTH TO 0.7 MILE NORTH OF LAMBERT ROAD UNDERCROSSING
QA Service Level1 (Verified on 05/31/2019)

Sample Information

Sample Taken Date08/07/2023 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/03/2023
Sample typeProduction Start-Up A brief description of the sample3/4" HMA-A-SP R15 0.50% LAS
The quantity of what the sample constitutes17 boxes of HMA, 2 Qts of oil, 4 Bags of AGG, 2 bags of RAP From where was the sample collectedManufacturer
First name of sampler or witnessed byCuong Last name of sampler or witnessed byPham
Title of sampler Telephone number of sampler
Laboratory sample identification0400A-23 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan-Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number220831 CORD SJR

Test Details

DIME Sample ID: 2023-08-07-5
DIME Test ID: 2023-08-07-5-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-08-24

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Antonio Torres
Date of test: 08/09/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2118.6 g
Mass Loss: 111.8 g
Correction Factor (Percent by mass of HMA Specimen): 0.37 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.77 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/24/2023