Summary for Test 2023-08-03-71-2

Test performed: AASHTO T240-17

Project Information

Project IdentifiersProject ID: 213749
DEA: 120C1104
EFIS: 1200000633
DIST-CO-RTE-PM12-ORA-57-20.3/21.6
Award Date04/19/2019
Closeout DateNot set
Work DescriptionSR-57 Lambert Interchange Project: WIDEN BRIDGES AND CONSTRUCT RW, SW, HMA, JPCP AND ELECTRICAL SYSTEMS.
Location DescriptionORANGE COUNTY IN BREA FROM 0.6 MILE SOUTH TO 0.7 MILE NORTH OF LAMBERT ROAD UNDERCROSSING
QA Service Level1 (Verified on 05/31/2019)

Sample Information

Sample Taken Date08/03/2023 Sample Unique Key71
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/07/2023
Sample typeProduction Start-Up A brief description of the samplePG Asphalt Binder
The quantity of what the sample constitutes1 Quart Can From where was the sample collectedSupplier
First name of sampler or witnessed byCuong Pham Last name of sampler or witnessed byCuong Pham
Title of sampler Telephone number of sampler
Laboratory sample identification0400-23 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan - Corona Drum Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeYes
Multigrade TypePG 64-16 / PG 64-10 Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2023-08-03-71
DIME Test ID: 2023-08-03-71-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2023-08-21

Test Results


Is mass change based on one or two containers?: Two
Input Type: Measured
Tester's full name: Sm Ali
Date of test: 08/14/2023
Any material loss from containers during heating process/testing?: No
Mass of empty container #1: 172.801 grams
Mass of empty container #2: 172.871 grams
Mass of container #1 before test (m1i): 207.906 grams
Mass of container #2 before test (m2i): 207.867 grams
Mass of container #1 after test (m1f): 207.838 grams
Mass of container #2 after test (m2f): 207.800 grams
Average mass change: -0.193 percent
General comments (publicly viewable) (Max 1000 characters): - 0.193 + 0.006 = - 0.187

Test was verified on 8/21/2023