Summary for Test 2023-04-18-24-9
Test performed: ASTM C430-8Project Information
Project Identifiers | Project ID: 8801 DEA: AML-CEM EFIS: AML-CEM |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for Cementitious Materials for use in Concrete Authorized Material List (AML) |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 04/18/2023 | Sample Unique Key | 24 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/12/2012 |
Sample type | Authorization | A brief description of the sample | PLC Blended Cement |
The quantity of what the sample constitutes | 1 Bucket | From where was the sample collected | Source |
First name of sampler or witnessed by | na | Last name of sampler or witnessed by | na |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | CM23R301 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Pan Pacific Cement | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Cementitious | Brand | Pan Pacific |
---|---|---|---|
Mill | Tan Thang | Type of Cementitious Material | Blended Cement |
Test Details
DIME Sample ID: 2023-04-18-24
DIME Test ID: 2023-04-18-24-9
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C430-8: Standard Test Method for Fineness of Hydraulic Cement by the 45-μm (No. 325) Sieve
Test Release Date: 2023-08-09
Test Results
Type of Material: Hydraulic Cement
Input Type: Measured
Tester's full name: Anthony Valdez
Date of test: 06/29/2023
Residue from the sample retained on the No. 325 sieve (Rs): 0.0151 grams
Sieve correction factor (C): 97.02
Corrected residue, % (Rc): 3 %
Fineness of the cement as the corrected percentage passing the 45 micrometers sieve (No. 325): 97 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/9/2023 ✔