Summary for Test 2023-04-18-24-7

Test performed: ASTM C187-16

Project Information

Project IdentifiersProject ID: 8801
DEA: AML-CEM
EFIS: AML-CEM
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date04/18/2023 Sample Unique Key24
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/12/2012
Sample typeAuthorization A brief description of the samplePLC Blended Cement
The quantity of what the sample constitutes1 Bucket From where was the sample collectedSource
First name of sampler or witnessed byna Last name of sampler or witnessed byna
Title of sampler Telephone number of sampler
Laboratory sample identificationCM23R301 Linked DIME Sample ID
The fabricator/manufacturer/facility namePan Pacific Cement Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeCementitious BrandPan Pacific
MillTan Thang Type of Cementitious MaterialBlended Cement

Test Details

DIME Sample ID: 2023-04-18-24
DIME Test ID: 2023-04-18-24-7
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C187-16: Standard Test Method for Amount of Water Required for Normal Consistency of Hydraulic Cement Paste (Water Normal Consistency)
Test Release Date: 2023-08-09

Test Results


Input Type: Measured
Tester's full name: Anthony Valdez
Date of test: 06/21/2023
Mass of Water: 165 g
Mass of Dry Cement: 650 g
Water required for normal consistency: 25.50 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/9/2023