Summary for Test 2023-07-03-1-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 212112
DEA: 080C2514
EFIS: 0816000076
COOP: 081645
DIST-CO-RTE-PM08-SBD-10-0.0/13.2
Award Date06/06/2018
Closeout DateNot set
Work DescriptionDesign-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes
Location DescriptionLA/SBD County Line to PM 13.2 near I-15
QA Service Level1 (Verified on 10/16/2019)

Sample Information

Sample Taken Date07/03/2023 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing07/07/2023
Sample typeQuality Assurance A brief description of the sample#4 1'-6" welded hoops
The quantity of what the sample constitutes29 pcs From where was the sample collectedFabricator
First name of sampler or witnessed byJoaquin Last name of sampler or witnessed byMoreno
Title of sampler Telephone number of sampler7146990897
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCMC Rebar San Bernadino Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4130116
Hoop Manufacturer Lot Number(s)30 Material Standard CodeASTM A706
Material Grade60 Rebar Size#4
Diameter of Hoop1'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Steel Arizona
Welding CompanyCMC Steel San Bernardino Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2023-07-03-1
DIME Test ID: 2023-07-03-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2023-07-11

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 07/11/2023
UTM: 400kip
Temperature: 72 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11304/13mm0.219985.6699928Ok Neckingaauvinen

General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 7/11/2023