Summary for Test 2023-07-03-21-1
Test performed: ASTM A370-20Project Information
Project Identifiers | Project ID: 213749 DEA: 120C1104 EFIS: 1200000633 |
---|---|
DIST-CO-RTE-PM | 12-ORA-57-20.3/21.6 |
Award Date | 04/19/2019 |
Closeout Date | Not set |
Work Description | SR-57 Lambert Interchange Project: WIDEN BRIDGES AND CONSTRUCT RW, SW, HMA, JPCP AND ELECTRICAL SYSTEMS. |
Location Description | ORANGE COUNTY IN BREA FROM 0.6 MILE SOUTH TO 0.7 MILE NORTH OF LAMBERT ROAD UNDERCROSSING |
QA Service Level | 1 (Verified on 05/31/2019) |
Sample Information
Sample Taken Date | 07/03/2023 | Sample Unique Key | 21 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/06/2023 |
Sample type | Quality Assurance | A brief description of the sample | Ductile Iron Casting |
The quantity of what the sample constitutes | 321 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Debbie | Last name of sampler or witnessed by | Ozuna |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Dywidag | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM6 - Ductile Iron Cast Samples | Heat Number (s) | C223 |
---|---|---|---|
Part Number (s) | 68 27 172 | Material Specification | A536 |
Grades | 80-55-06 | Metal Foundry Manufacturer (Mill) | Farrar Corporation |
Prestressing Manufacturer | Farrar Corporation |
Test Details
DIME Sample ID: 2023-07-03-21
DIME Test ID: 2023-07-03-21-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2023-07-12
Test Results
Number of Samples: 2
Input Type: Calculated
Tester's full name: aauvinen
Date of test: 07/07/2023
UTM: 67kip
Temperature: 72 F
Num | Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | C223 | 0.504 | 0.1995 | 64846 | 113159 | 8.2 | aauvinen | |
2 | C223 | 0.503 | 0.19871 | 65295 | 113894 | 8.2 | aauvinen |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Test was verified on 7/12/2023 ✔