Summary for Test 2023-05-23-79-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 993773
DEA: 021H5004
EFIS: 0216000045
DIST-CO-RTE-PM02-TRI-3,299-VAR
Award Date11/14/2022
Closeout DateNot set
Work DescriptionSTRUCT CONC BRIDGE, POLYESTER CONC OVERLAY & ROCK SLOPE PROTECTION.
Location DescriptionTRINITY COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 04/25/2022)

Sample Information

Sample Taken Date05/23/2023 Sample Unique Key79
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/02/2023
Sample typeQuality Assurance A brief description of the sampleStainless Steel Couplers
The quantity of what the sample constitutes16 From where was the sample collectedManufacturer
First name of sampler or witnessed byNA Last name of sampler or witnessed byNA
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCamblin Steel Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade75 Rebar ManufacturerNorth American Stainless
Coupler ManufacturerCMC Intermediate Assembler or Fabricator
Rebar Size#6 Coupler ModelTru Splice
Coating StandardsASTM A123 galvanized Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)NA Rebar Heat Number(s)V56K-RA71565
Rebar Size 2 Coupler Unique IDNot on AML

Test Details

DIME Sample ID: 2023-05-23-79
DIME Test ID: 2023-05-23-79-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2023-06-30

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 06/29/2023
UTM: 400kip
Temperature: 72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
13No. 6/19mm100.4446189104976Service Splice Broke in Threadsaauvinen

General comments (publicly viewable) (Max 1000 characters): Service Splice Broke in Threads
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 6/30/2023