Summary for Test 2023-06-10-6-1

Test performed: ASTM C293-10

Project Information

Project IdentifiersProject ID: 212112
DEA: 080C2514
EFIS: 0816000076
COOP: 081645
DIST-CO-RTE-PM08-SBD-10-0.0/13.2
Award Date06/06/2018
Closeout DateNot set
Work DescriptionDesign-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes
Location DescriptionLA/SBD County Line to PM 13.2 near I-15
QA Service Level1 (Verified on 10/16/2019)

Sample Information

Sample Taken Date06/10/2023 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/20/2023
Sample typeQuality Assurance A brief description of the samplecast concrete beams
The quantity of what the sample constitutes3 From where was the sample collectedJob Site
First name of sampler or witnessed byjulian Last name of sampler or witnessed byCarmora
Title of samplerC3 Telephone number of sampler
Laboratory sample identificationset 14A B C Linked DIME Sample ID
The fabricator/manufacturer/facility nameLANEsecurity paving Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberG3-21-PRS-243
The truck number from where the sample was collectedNA The batch plant ticket number from where the sample was collectedG3-21-PRS-243
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedAT THE JOBSITE Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-06-10-6
DIME Test ID: 2023-06-10-6-1
Testing Lab: CT D08 - Blythe Field Testing Laboratory
Test Method: ASTM C293-10: Standard Test Method for Flexural Strength of Concrete (Using Simple Beam With Center-Point Loading)
Test Release Date: 2023-06-23

Test Results


Unit system used?: US Units
Input Type: Measured
Tester's full name: Julius E/CHIJOKE
Date of test: 06/20/2023
Identification number: 14A
Width of specimen: 6 inch
Depth of specimen: 6 inch
Span length of specimen: 18 inch
Maximum load applied: 8930 lb
Curing history and apparent moisture condition of the specimen: CURING ROOM
If specimen was capped, ground or if leather shims were used: NO
Defects in specimen: NO
Age of specimen: 10 days
Modulus of rupture: 1115 psi
General comments (publicly viewable) (Max 1000 characters): AVE 790PSI FOR 650 PSI OF 10 DAYS BREAK

Test was verified on 6/23/2023