Summary for Test 2023-06-08-1-1

Test performed: ASTM A615-20

Project Information

Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Award DateNot set
Closeout Date11/01/2022
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date06/08/2023 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing06/12/2023
Sample typeQuality Assurance A brief description of the sampleThread Bar
The quantity of what the sample constitutes585 From where was the sample collectedFabricator
First name of sampler or witnessed byBrian Last name of sampler or witnessed byMurray
Title of samplerQA Inspector Telephone number of sampler2134354055
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameNucor Skyline Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL140-073-23 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingAuthorization Testing
Threaded Bar SpecificationASTM A615 Threaded Bar Grade80
Threaded Bar TypeDeformed Rebar Size#8
Nut Specification for Threaded Barn/a System ManufacturerNucor Skyline
Epoxy Coating ColorNA Threaded Bar ApplicationThreaded Bar
Coating StandardsUncoated Bar Heat Number(s)3700039063
Nut Heat Number(s)n/a Bar Lot Number370003906320
Nut Lot Numbern/a Coupler Heat Number(s)n/a
Coupler Graden/a

Test Details

DIME Sample ID: 2023-06-08-1
DIME Test ID: 2023-06-08-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A615-20: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2023-06-20

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: rmacias
Date of test: 06/13/2023
UTM: 400kip
Temperature: 72 f
NumSampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)CommentsTested By
1No.8/25mm0.791167738448714.51Tensile ok neckingrmacias

General comments (publicly viewable) (Max 1000 characters): Tensile ok necking
Test Graph
Source: Bluehill Data Point File
WARNING: strain or stress not found in data points imported from Instron machine.

Test was verified on 6/20/2023