Summary for Test 2023-04-24-103-1
Test performed: CTM 521-June 2020Project Information
Project Identifiers | Project ID: 214989 DEA: 050L7224 EFIS: 0515000098 |
---|---|
DIST-CO-RTE-PM | 05-SLO-1-34.5 |
Award Date | 10/13/2021 |
Closeout Date | Not set |
Work Description | REPLACE BRIDGE. |
Location Description | SAN LUIS OBISPO COUNTY NEAR MORRO BAY AT OLD CREEK BRIDGE |
QA Service Level | 1 (Verified on 09/03/2020) |
Sample Information
Sample Taken Date | 04/24/2023 | Sample Unique Key | 103 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/25/2023 |
Sample type | Quality Assurance | A brief description of the sample | 2 6x12 concrete cylinders |
The quantity of what the sample constitutes | PCC Abut 1 App Slab | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Garret | Last name of sampler or witnessed by | Hilton |
Title of sampler | ASR | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Calportland | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | Abut 1 Approach Slab |
Material Information
Material Type | Concrete | The concrete mix design number | 725RHS2010 |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | NA | |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | Mix Truck | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2023-04-24-103
DIME Test ID: 2023-04-24-103-1
Testing Lab: CT D05 - Whitley Gardens Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2023-05-22
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Kyle Engen
Date of test: 05/22/2023
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 6.04 in
Average diameter of cylinder 2: 6.04 in
Maximum load on cylinder 1: 187478 lb
Maximum load on cylinder 2: 190074 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.65 in^2
Cross sectional area of cylinder 2: 28.65 in^2
Compressive strength of cylinder 1: 6543.7 psi
Compressive strength of cylinder 2: 6634.3 psi
Compressive strength (to nearest 10 psi): 6590 psi
General comments (publicly viewable) (Max 1000 characters):
Test File Attachments
File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
---|---|---|---|---|---|
05-0L7224_37073_230522_CTM 521_KEE_2x_Abut1_AppSlab | 184.95 KB | 05/22/2023 | 2023-04-24-103-1 | Info |
Test was verified on 5/22/2023 ✔