Summary for Test 2023-04-13-64-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 214989
DEA: 050L7224
EFIS: 0515000098
DIST-CO-RTE-PM05-SLO-1-34.5
Award Date10/13/2021
Closeout DateNot set
Work DescriptionREPLACE BRIDGE.
Location DescriptionSAN LUIS OBISPO COUNTY NEAR MORRO BAY AT OLD CREEK BRIDGE
QA Service Level1 (Verified on 09/03/2020)

Sample Information

Sample Taken Date04/13/2023 Sample Unique Key64
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/14/2023
Sample typeQuality Assurance A brief description of the sample6x12 concrete cylinders
The quantity of what the sample constitutesLeft Deck of Old Creek Bridge From where was the sample collectedJob Site
First name of sampler or witnessed byGarret Last name of sampler or witnessed byHilton
Title of samplerASR Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCalPortland Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameDeck Left

Material Information

Material TypeConcrete The concrete mix design number725RHS2010
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedNA
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedMix Truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-04-13-64
DIME Test ID: 2023-04-13-64-1
Testing Lab: CT D05 - Whitley Gardens Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2023-05-12

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Kyle Engen
Date of test: 05/11/2023
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 6.04 in
Average diameter of cylinder 2: 6.04 in
Maximum load on cylinder 1: 167931 lb
Maximum load on cylinder 2: 163957 lb
Type of fracture pattern of cylinder 1: 4
Type of fracture pattern of cylinder 2: 4
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.65 in^2
Cross sectional area of cylinder 2: 28.65 in^2
Compressive strength of cylinder 1: 5861.5 psi
Compressive strength of cylinder 2: 5722.8 psi
Compressive strength (to nearest 10 psi): 5790 psi
General comments (publicly viewable) (Max 1000 characters):

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
05-0L7224_37072_230511_CTM 521_KEE_2x_Left Deckpdf189.81 KB05/12/20232023-04-13-64-1   Info

Test was verified on 5/12/2023