Summary for Test 2023-01-27-1-5
Test performed: ASTM F606-21Project Information
Project Identifiers | Project ID: 215649 DEA: 043G4884 EFIS: 0412000088 |
---|---|
DIST-CO-RTE-PM | 04-SM-92-R14.4/R18.8 |
Award Date | 09/01/2022 |
Closeout Date | Not set |
Work Description | CLEAN AND PAINT STEEL BRIDGE TOWERS, REPLACE HIGH STRENGTH BOLTS. |
Location Description | SAN MATEO COUNTY IN FOSTER CITY FROM SAN MATEO-HAYWARD BRIDGE TO ALAMEDA COUNTY LINE |
QA Service Level | 1 (Verified on 03/29/2021) |
Sample Information
Sample Taken Date | 01/27/2023 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/31/2023 |
Sample type | Quality Assurance | A brief description of the sample | 1-8x4 F1852 TC Bolts |
The quantity of what the sample constitutes | 650 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Dylan | Last name of sampler or witnessed by | LaRose |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Unytite, Inc. | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 10784400 10781200 | Nut Mfg. Lot Number(s) | 37298-5805312503 36188-5805022403 |
Washer Mfg. Lot Number(s) | 0722-390 E1516 | Bolt Specification | A325 |
Bolt Length(s) | 4" | Nut Specification | A563 DH |
Washer Specification | F436 | Finish | MG |
Diameter/Size | 1" | Bolt Mfg. Lot Number | 37541-10784400, 36932-10781200 |
Rocap Test Requirement(s) | No RoCap required. | Lubricant Requirements(s) | None. |
Test Details
DIME Sample ID: 2023-01-27-1
DIME Test ID: 2023-01-27-1-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2023-02-07
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 02/02/2023
UTM: 450kip
Temperature: 72 f
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1B | 95030 | Nut Proof Load |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 2/7/2023 ✔