Summary for Test 2022-12-07-28-1

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 993776
DEA: 040J3004
EFIS: 0413000433
DIST-CO-RTE-PM04-SON-1-26.7/27.1
Award Date07/08/2022
Closeout DateNot set
Work DescriptionCONSTRUCTING RETAINING WALL AND CONFINEMENT SYSTEM TO RESTORE SLIPOUT.
Location DescriptionSONOMA COUNTY NEAR JENNER FROM 0.3 MILE TO 0.7 MILE NORTH OF MEYERS GRADE ROAD
QA Service Level1 (Verified on 05/11/2022)

Sample Information

Sample Taken Date12/07/2022 Sample Unique Key28
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/07/2022
Sample typeQuality Assurance A brief description of the sample6 Cylinders 4x8
The quantity of what the sample constitutes6 Cylinders 4x8 From where was the sample collectedJob Site
First name of sampler or witnessed byFabio Last name of sampler or witnessed byLa Serna
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameArgonaut Constructors Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberSL-4700CG
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedSL-4700CG
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedJobsite Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2022-12-07-28
DIME Test ID: 2022-12-07-28-1
Testing Lab: CT HQ - QASI Bay Area Field Office
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2022-12-15

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Nikhil Moon
Date of test: 12/14/2022
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 78160 lb
Maximum load on cylinder 2: 80170 lb
Maximum load on cylinder 3: 78910 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Correction factor for cylinder 3: 1
Age of specimen: 7 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 12.566 in^2
Cross sectional area of cylinder 2: 12.566 in^2
Cross sectional area of cylinder 3: 12.566 in^2
Compressive strength (to nearest 10 psi): 6290 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/15/2022