Sample Record

Owner Lab

  • CT HQ - QASI Bay Area Field Office

DIME Sample ID 2022-12-07-28

Project Information

Project IdentifiersProject ID: 993776
DEA: 040J3004
EFIS: 0413000433
DIST-CO-RTE-PM04-SON-1-26.7/27.1
Award Date07/08/2022
Closeout DateNot set
Work DescriptionCONSTRUCTING RETAINING WALL AND CONFINEMENT SYSTEM TO RESTORE SLIPOUT.
Location DescriptionSONOMA COUNTY NEAR JENNER FROM 0.3 MILE TO 0.7 MILE NORTH OF MEYERS GRADE ROAD
QA Service Level1 (Verified on 05/11/2022)

Sample Information

Sample Taken Date12/07/2022 Sample Unique Key28
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/07/2022
Sample typeQuality Assurance A brief description of the sample6 Cylinders 4x8
The quantity of what the sample constitutes6 Cylinders 4x8 From where was the sample collectedJob Site
First name of sampler or witnessed byFabio Last name of sampler or witnessed byLa Serna
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameArgonaut Constructors Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberSL-4700CG
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedSL-4700CG
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedJobsite Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2022-12-07-28-1ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensNikhil Moon, CT HQ - QASI Bay Area Field Office12/14/2022Nikhil Moon
Yes
12/15/2022
2022-12-07-28-2ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensNikhil Moon, CT HQ - QASI Bay Area Field Office01/06/2023Nikhil Moon
No
Compression Testing machine capacity is not greater than 7000 psi Info

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2022-12-07-28-1 ASTM C39-17a (Verified)
DIME Test ID: 2022-12-07-28-2 ASTM C39-17a