Summary for Test 2016-09-21-8-5
Test performed: ASTM A615-15Project Information
Project Identifiers | Project ID: 210569 DEA: 083555V4 EFIS: 0814000086 |
---|---|
DIST-CO-RTE-PM | 08-SBD-15-42.5/46.0 |
Award Date | 11/05/2015 |
Closeout Date | 01/18/2022 |
Work Description | WIDEN I-15, RECONSTRUCT 3 IC'S, CONSTRUCT 2 NEW BR AND WIDEN 3 BR. |
Location Description | SAN BERNARDINO COUNTY IN VICTORVILLE FROM 0.5 MILE NORTH OF MOJAVE DRIVE TO 1.5 MILE NORTH OF STODDARD WELLS ROAD OVERCROSSING |
QA Service Level | 1 (Verified on 10/15/2015) |
Sample Information
Sample Taken Date | 09/21/2016 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/28/2016 |
Sample type | Quality Assurance | A brief description of the sample | A615 Grade 75 Threaded Bar |
The quantity of what the sample constitutes | 6 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Russell | Last name of sampler or witnessed by | Lynch |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Williams Form | Transportation Laboratory (TL) Number | C970420 Thru C970424 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L9610916 Thru L9611316 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Production Testing |
---|---|---|---|
Threaded Bar Specification | ASTM A615 | Threaded Bar Grade | 75 |
Threaded Bar Type | Deformed | Rebar Size | #9 |
Nut Specification for Threaded Bar | AISI 1045 | System Manufacturer | Williams Form |
Epoxy Coating Color | Purple | Threaded Bar Application | Soil Nail |
Coating Standards | ASTM A934 epoxy | Bar Heat Number(s) | |
Nut Heat Number(s) | Bar Lot Number | ||
Nut Lot Number | Coupler Heat Number(s) | ||
Coupler Grade |
Test Details
DIME Sample ID: 2016-09-21-8
DIME Test ID: 2016-09-21-8-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2016-09-29
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 09/28/2016
UTM: 400KIP
Temperature: 72 F
Num | Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 5 | #9 Bar Heat #PL16205339, Nut Heat #9H5D | L9611016 | 1 | 125974 | 94404 | 8.6 | A615 Bar & Nut | Fred |
General comments (publicly viewable) (Max 1000 characters): A615 Bar & Nut
Test Graph
Source: Partner Data Point FileTest was verified on 9/29/2016 ✔