Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2016-09-21-8

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210569
DEA: 083555V4
EFIS: 0814000086
DIST-CO-RTE-PM08-SBD-15-42.5/46.0
Award Date11/05/2015
Closeout Date01/18/2022
Work DescriptionWIDEN I-15, RECONSTRUCT 3 IC'S, CONSTRUCT 2 NEW BR AND WIDEN 3 BR.
Location DescriptionSAN BERNARDINO COUNTY IN VICTORVILLE FROM 0.5 MILE NORTH OF MOJAVE DRIVE TO 1.5 MILE NORTH OF STODDARD WELLS ROAD OVERCROSSING
QA Service Level1 (Verified on 10/15/2015)

Sample Information

Sample Taken Date09/21/2016 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/28/2016
Sample typeQuality Assurance A brief description of the sampleA615 Grade 75 Threaded Bar
The quantity of what the sample constitutes6 From where was the sample collectedManufacturer
First name of sampler or witnessed byRussell Last name of sampler or witnessed byLynch
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameWilliams Form Transportation Laboratory (TL) NumberC970420 Thru C970424
Inspector Lot Number from the Transportation Laboratory (TL) FormL9610916 Thru L9611316 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingProduction Testing
Threaded Bar SpecificationASTM A615 Threaded Bar Grade75
Threaded Bar TypeDeformed Rebar Size#9
Nut Specification for Threaded BarAISI 1045 System ManufacturerWilliams Form
Epoxy Coating ColorPurple Threaded Bar ApplicationSoil Nail
Coating StandardsASTM A934 epoxy Bar Heat Number(s)
Nut Heat Number(s) Bar Lot Number
Nut Lot Number Coupler Heat Number(s)
Coupler Grade

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2016-09-21-8-1ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory09/28/2016Fred
Yes
09/29/2016A615 Bar & Nut
2016-09-21-8-2ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory09/28/2016Fred
Yes
09/29/2016A615 Bar & Nut
2016-09-21-8-3ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory09/28/2016Fred
Yes
09/29/2016A615 Bar & Nut
2016-09-21-8-4ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory09/28/2016Fred
Yes
09/29/2016A615 Bar & Nut
2016-09-21-8-5ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory09/28/2016Fred
Yes
09/29/2016A615 Bar & Nut
2016-09-21-8-6ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory09/28/2016Fred
Yes
09/29/2016A615 Bar & Nut
2016-09-21-8-7ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory09/28/2016Fred Saylor
Yes
09/29/2016
2016-09-21-8-8ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory09/28/2016Fred Saylor
Yes
09/29/2016
2016-09-21-8-9ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)Fred Saylor, CT HQ - Sacramento Structural Materials Testing Laboratory09/28/2016Fred Saylor
Yes
09/29/2016

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-09-21-8-1 ASTM A615-15 (Verified)
DIME Test ID: 2016-09-21-8-2 ASTM A615-15 (Verified)
DIME Test ID: 2016-09-21-8-3 ASTM A615-15 (Verified)
DIME Test ID: 2016-09-21-8-4 ASTM A615-15 (Verified)
DIME Test ID: 2016-09-21-8-5 ASTM A615-15 (Verified)
DIME Test ID: 2016-09-21-8-6 ASTM A615-15 (Verified)
DIME Test ID: 2016-09-21-8-7 ASTM A934-13 (Verified)
DIME Test ID: 2016-09-21-8-8 ASTM A934-13 (Verified)
DIME Test ID: 2016-09-21-8-9 ASTM A934-13 (Verified)