Summary for Test 2022-10-21-38-1

Test performed: AASHTO T209-12

Project Information

Project IdentifiersProject ID: 214666
DEA: 022H8104
EFIS: 0217000012
DIST-CO-RTE-PM02-TRI-299-1.67/45.12
Award Date03/03/2022
Closeout Date08/11/2023
Work DescriptionTRINITY CULVERTS
Location DescriptionCULVERT REHABILITATION IN TRINITY COUNTY NEAR SALYER AT VARIOUS LOCATIONS FROM 0.1 MILE WEST OF WHITE HOUSE GULCH ROAD TO 0.4 MILE WEST OF SLATTERY POND ROAD.
QA Service Level1 (Verified on 03/02/2020)

Sample Information

Sample Taken Date10/21/2022 Sample Unique Key38
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/21/2022
Sample typeDepartment Acceptance A brief description of the sample16 boxes of Lime Treated 3/4-inch Type A HMA (eq. PG 64-28 M) with 24.0% RAP and virgin PG 58-34 M from Valero (Benicia, CA)
The quantity of what the sample constitutesProduction Start-Up Evaluation From where was the sample collectedManufacturer
First name of sampler or witnessed byJD Last name of sampler or witnessed byAtkinson
Title of samplerConsultant Telephone number of sampler
Laboratory sample identificationD79176 Linked DIME Sample ID
The fabricator/manufacturer/facility nameTullis – Northstate Asphalt (Redding, CA) Transportation Laboratory (TL) Number858105
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number

Test Details

DIME Sample ID: 2022-10-21-38
DIME Test ID: 2022-10-21-38-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2022-10-31

Test Results


Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Darrell Valasek
Date of test: 10/24/2022
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7335.8 grams
Mass of oven-dry sample in air for Sample 1: 2573.7 grams
Mass of container filled with the sample and water for Sample 1: 8883.0 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.507
Theoretical maximum density at 25°C (77°F): 156.0 lb/ft^3
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/31/2022