Summary for Test 2022-10-21-38-1
Test performed: AASHTO T209-12Project Information
Project Identifiers | Project ID: 214666 DEA: 022H8104 EFIS: 0217000012 |
---|---|
DIST-CO-RTE-PM | 02-TRI-299-1.67/45.12 |
Award Date | 03/03/2022 |
Closeout Date | 08/11/2023 |
Work Description | TRINITY CULVERTS |
Location Description | CULVERT REHABILITATION IN TRINITY COUNTY NEAR SALYER AT VARIOUS LOCATIONS FROM 0.1 MILE WEST OF WHITE HOUSE GULCH ROAD TO 0.4 MILE WEST OF SLATTERY POND ROAD. |
QA Service Level | 1 (Verified on 03/02/2020) |
Sample Information
Sample Taken Date | 10/21/2022 | Sample Unique Key | 38 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/21/2022 |
Sample type | Department Acceptance | A brief description of the sample | 16 boxes of Lime Treated 3/4-inch Type A HMA (eq. PG 64-28 M) with 24.0% RAP and virgin PG 58-34 M from Valero (Benicia, CA) |
The quantity of what the sample constitutes | Production Start-Up Evaluation | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | JD | Last name of sampler or witnessed by | Atkinson |
Title of sampler | Consultant | Telephone number of sampler | |
Laboratory sample identification | D79176 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Tullis – Northstate Asphalt (Redding, CA) | Transportation Laboratory (TL) Number | 858105 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number |
Test Details
DIME Sample ID: 2022-10-21-38
DIME Test ID: 2022-10-21-38-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2022-10-31
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Darrell Valasek
Date of test: 10/24/2022
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7335.8 grams
Mass of oven-dry sample in air for Sample 1: 2573.7 grams
Mass of container filled with the sample and water for Sample 1: 8883.0 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.507
Theoretical maximum density at 25°C (77°F): 156.0 lb/ft^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/31/2022 ✔