Summary for Test 2022-06-23-85-4
Test performed: CTM 217-June 2011Project Information
Project Identifiers | Project ID: 7613 DEA: 071218W4 EFIS: 0700021119 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-29.4/31.6 |
Award Date | 11/29/2012 |
Closeout Date | 07/31/2023 |
Work Description | REALIGN ROUTE 5 AND RAILROAD TRACKS AND RECONFIGURE ON- AND OFF-RAMPS. |
Location Description | LOS ANGELES COUNTY IN BURBANK FROM WEST MAGNOLIA BOULEVARD OVERCROSSING TO 0.3 MILE NORTH OF BUENA VISTA STREET/WINONA AVENUE UNDERCROSSING |
QA Service Level | 1 (Verified on 10/08/2012) |
Sample Information
Sample Taken Date | 06/23/2022 | Sample Unique Key | 85 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 06/27/2022 |
Sample type | Department Acceptance | A brief description of the sample | belt cut |
The quantity of what the sample constitutes | 140CY | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Luis | Last name of sampler or witnessed by | Acosta |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Security Paving La Mirada | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-19-0025 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | belt | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
The concrete mix design number | G3-15-STR-002 | Lot number | |
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2022-06-23-85
DIME Test ID: 2022-06-23-85-4
Testing Lab: CT D07 - Plant Services
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2022-10-17
Test Results
Number of tests: 3
Input Type: Calculated
Tester's full name: M Compas
Date of test: 07/07/2022
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 4.6
Sand reading (test 1): 3.8
Clay reading (test 2): 4.4
Sand reading (test 2): 3.7
Clay reading (test 3): 4.6
Sand reading (test 3): 3.9
Sand equivalent (test 1): 83
Sand equivalent (test 2): 85
Sand equivalent (test 3): 85
Sand equivalent before temperature correction: 85
Sand equivalent after temperature correction: 85
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/17/2022 ✔